Hot and cold water dispenser
Temperature control range: 10℃-40℃
Cooling capacity range: 9.9 KW-148 KW
Heating capacity range: 6 KW-72 KW
Temperature control accuracy: ±1℃
Keywords:
Hot and cold water dispenser
Category:
Hotline:
Detailed Description
Main Features
1. Dual Control of Heating and Cooling: Integrates refrigeration and heating functions, enabling rapid heating and cooling to meet diverse temperature requirements of different processes;
2. High Efficiency and Energy Saving: Optimized refrigeration and heating systems, coupled with high-efficiency compressors and heating elements, offer high energy efficiency ratios, low operating costs, and significant energy savings;
3. Stable and Reliable: Core components are selected from internationally renowned brands, ensuring high efficiency and stability during long-term, high-load operation, low failure rate, and long service life;
4. Multifunctional Protection: Features multiple safety protection functions, including overload protection, high and low pressure protection, and antifreeze protection, ensuring safe and reliable equipment operation.
5. Flexible Adaptability: Can be customized to different refrigeration capacities, cooling media, and operating temperature ranges according to customer needs, meeting diverse application scenarios.
Core Application Industries
Plastic Processing: Used for mold temperature control in plastic production equipment such as injection molding machines and extruders;
Pharmaceutical Manufacturing: Used for temperature control in pharmaceutical production equipment and laboratory R&D processes;
Food Processing: Used for temperature control in food heating, cooling, and fermentation processes;
Environmental Protection Industry: Used for temperature control in wastewater treatment, exhaust gas treatment, and soil heavy metal pollution control;
New Energy Field: Used for battery testing and fuel cell temperature control.
Model |
MK-03AS-6K |
MK-05AS-12K |
MK-10AS-18K |
MK-15AD-30K |
MK-20AD-36K |
MK-25AD-48K |
MK-50AD-72K |
||
Parameters |
|||||||||
Rated Cooling Capacity |
KW/hr |
50HZ |
9.90 |
14.90 |
29.80 |
39.20 |
62.60 |
74.00 |
148.00 |
Kcal |
50HZ |
8514 |
12814 |
25628 |
33712 |
53836 |
63640 |
127280 |
|
Rated Heating Capacity |
KW/hr |
50HZ |
6.00 |
12.00 |
18.00 |
30.00 |
36.00 |
48.00 |
72.00 |
Kcal |
50HZ |
5160 |
10320 |
15480 |
25800 |
30960 |
41280 |
61920 |
|
Temperature Control Range |
10℃-40℃ |
||||||||
Operating Ambient Temperature Range |
-20℃-42℃ |
||||||||
Power Supply |
3N-380V/50HZ |
||||||||
Rated Total Cooling Power |
KW |
3.63 |
5.09 |
9.19 |
12.45 |
18.57 |
23.20 |
43.94 |
|
Rated Total Heating Power |
6.55 |
12.55 |
18.55 |
30.75 |
37.10 |
50.20 |
74.20 |
||
Compressor |
Type |
Fully Enclosed Scroll Compressor |
|||||||
Quantity |
1 |
1 |
1 |
2 |
2 |
2 |
4 |
||
Rated Power KW |
2.80 |
4.10 |
4.1*2 |
5.5*2 |
8.25*2 |
9.95*2 |
9.95*4 |
||
Refrigerant |
Type |
R22 |
|||||||
Charging Quantity KG |
2.4 |
4.0 |
4*2 |
6.4*2 |
8*2 |
9.6*2 |
9.6*4 |
||
Throttling Method |
External Balance Thermostatic Expansion Valve |
||||||||
Condenser |
Form |
High-efficiency copper tube corrugated aluminum fin type |
|||||||
Fan |
Air Volume M 3/h |
3000 |
5000 |
10000 |
15000 |
20000 |
25000 |
50000 |
|
Rated Power KW |
0.28 |
0.44 |
0.44 |
0.7 |
0.97 |
1.10 |
1.94 |
||
Evaporator |
Type |
Stainless Steel Plate Evaporator |
|||||||
Flow Rate M 3/h |
1.97 |
2.97 |
5.93 |
7.80 |
12.46 |
14.73 |
29.46 |
||
Inlet and Outlet Pipe Diameter G |
G1" |
G1" |
G1-1/2" |
G2" |
G2" |
G2" |
G2-1/2" |
||
Heater |
Rated Power KW |
6 |
12 |
18 |
30 |
36 |
48 |
72 |
|
Water Pump |
Rated Power KW |
0.55 |
0.55 |
0.55 |
0.75 |
1.10 |
2.20 |
2.20 |
|
Rated Head m |
21 |
18 |
21 |
19 |
22 |
21 |
20 |
||
Machine Dimensions |
L/mm |
1200 |
1450 |
1800 |
1800 |
2000 |
2300 |
1900 |
|
W/mm |
600 |
720 |
900 |
900 |
1000 |
1000 |
1820 |
||
H/mm |
1450 |
1550 |
1750 |
1750 |
1980 |
1980 |
2200 |
||
Unit Weight |
KG |
260 |
350 |
480 |
550 |
680 |
780 |
1360 |
|
Note:
1. Table cooling capacity rating conditions: chilled water inlet temperature is 30℃, outlet temperature is 25℃, evaporation temperature is 5℃, and ambient temperature is 30℃;
2. When the ambient temperature is below 2℃ or the machine is not used for a long time, the accumulated water in the machine should be drained to prevent damage to the heat exchanger due to freezing;
3. Air-cooled units must be installed in a well-ventilated place (such as outdoors, on the roof), and ensure that the air duct system is unobstructed;
4. Specifications and performance may change due to product improvements without further notice.
Previous Page
Next Page
Related Products
Temperature control range: 5℃-25℃
Cooling capacity range: 2.94 KW-181.68 KW
Temperature control accuracy: ±1℃
Water-cooled industrial chiller
Temperature control range: 5℃-25℃
Cooling capacity range: 9.59 KW-198.12 KW
Temperature control accuracy: ±1℃
Temperature control range: 5℃-25℃
Cooling capacity range: 110 KW-1500 KW
Temperature control accuracy: ±1℃
Temperature control range: 5℃-25℃
Cooling capacity range: 110 KW-1530 KW
Temperature control accuracy: ±1℃